Shopping Cart

Your cart is empty.

Your cart is empty.

Replacement for Honeywell Furnace Integrated Pilot Module Ignition Control Circuit Board S8610U

Free shipping on orders over $29.99

$134.19

$ 59 .99 $59.99

In Stock
  • This is a Brand New Upgraded Furnace Pilot Ignition Control Circuit Board.
  • Upgrade Kit comes with wiring instructions and any hardware you may or may not need.


This is a Brand New Upgraded Furnace Pilot Ignition Control Circuit Board.


Michael
Reviewed in the United States on April 8, 2024
When I figured out why I had no heat I ordered this because #1 couldn't get the exact replacement the details said that all necessary parts and applicable DIRECTIONS where included not true just received the module. I searched other reviews to help installing it properly . Still have no heat . While still searching checking all of the relays, swiches, sensor's, voltages still no heat😡
ARE B
Reviewed in the United States on April 14, 2024
may have to modify your wiring, read the manual and you'll be fine
R. Jarboe
Reviewed in the United States on November 29, 2023
HVAC tech said the part would cost me 1K and I should probably just replace the furnace. Got this part instead did it myself in less than 10 minutes. Problem solved. Works great. As mentioned in another review the 24 volt wire had to be switched to TH-W. Comfortmaker Furnace.
Samarth
Reviewed in the United States on November 16, 2023
At first we believed this was an incorrect part that was sent. After conversations with the really helpful and kind customer service reps at Chip and Processor, we were provided guidance and assurance the part would work. Installing the part was easy to do with no HVAC experience and now our furnace works perfectly.
Robert baker
Reviewed in the United States on October 3, 2023
Heater stopped working replaced the part now it works what more can I say no problems after a couple years of the repair
Bret A. Scott
Reviewed in the United States on September 25, 2021
The igniter on my Burnham boiler failed, and I ordered this one to replace. The local cost was literally 3 times more at the time that I ordered it, and it seemed easy enough to install that I didn't call a heating/cooling service company to do the work. This unit is a later Honeywell design than the one it replaced, but the terminals are well labeled and screw hold-down positions are the same. The module was swapped in less than 10 minutes. Based on my experience, I think most handymen could make this repair, and it's a good time to replace the igniter cable (looks like a spark plug cable).
Charles Mooney
Reviewed in the United States on January 17, 2020
Used module to replace Honeywell S8600M igniter module that had no vent damper plug (see instructions) in a Kenmore Power Miser 80 furnace that was installed in 1990. No wiring had to be changed except 24 volt wire went to TH-W terminal in new module as indicated in the instructions. Worked first time without any problems.
Customer
Reviewed in the United States on January 17, 2019
As described
Recommended Products

$249.95

$ 98 .99 $98.99

4.7
Select Option

$136.99

$ 60 .99 $60.99

4.5
Select Option

$150.95

$ 60 .99 $60.99

4.3
Select Option

$105.00

$ 46 .99 $46.99

4.5
Select Option

$193.95

$ 82 .99 $82.99

4.3
Select Option

$143.83

$ 66 .99 $66.99

4.8
Select Option