  • ▲(1)Easy to Use: Simple operation.Needle indicates, convenience the user to read.
  • ▲(2)High Precision: Suitable for professional testing.
  • ▲(3)Easy to Carry: Handhold design,Small and simple package for easy carrying .
  • ▲(4)Shore C hardness tester is used in measuring the hardness of oak model micro porous material which includes vesicant when the compression ratio is 50%, the stress above 0.5kg/cm2. It also can be used in other similar hardness materials.
  • ▲(5)Type C: applicable to the hardness test of rubber microporous material.



Product Description

1
1
1
1

HFBTE Shore C Dual Needle Hardness Tester Durometer With Measure Range 10 To 90 HC For Foam Sponge Rubber Microporous Material Etc

Function:

  • Shore C hardness tester applies to the testing of microporous material which is used to make shoes, with compression rate 50 percent, stress 0.049 MPa or above, and this kind of material is made of rubber plastic and has blister in plastic.
  • This hardness gauge conforms to the regulations of GB/T531-99, GB2411-80, hg/t2489-93, JJG304-2003.

Features:

  • It is not necessary to observe the value in real time according to the change of the measuring angle. As long as the measurement is done, the driven pointer is directly positioned on the numerical scale of the measurement to be read conveniently, and the error caused by the change of the observation angle is eliminated.
  • Type C: applicable to the hardness test of rubber microporous material.
  • Needle indicates, convenience the user to read., high accuracy.
  • Handhold design, carry conveniently,

Technical Specifications

  • Calibration Value: 0 ~ 100HC
  • Recommended Range of Measurements: 10 ~ 90HC
  • Resolution: 1 HC
  • Pressure Head Size: SR 2.5 mm
  • End Pressure of Pressure Head: 0.55N ~ 8.05N
  • Outline Dimension: 115 x 60 x 25mm
  • Pressure Needle Range: 2.5 mm
  • End Pressure of Pressure Head: SR 2.5 mm
  • Weight: 0.16 kg

How to use:

  1. Place the sample on a solid surface, hold the hardness tester and the panel of the hardness tester is at an angle with the operator, and press the needle at least 12mm away from the surface of the test sample.
  2. Press the hardness tester into the sample steadily until the presser foot and the sample are completely in contact, and the driven needle will stay on the numerical scale of this test until the compression screw is turned to return to zero.
  3. Each sample shall be tested no less than 5 times, and the distance between each test point shall be at least 6mm. After the test, take the average value (the distance between the measuring points of the microporous material is at least 15mm).

Instructions for use:

  1. The pointer of the hardness tester should point to the zero position in a free state. If the pointer slightly deviates from the zero position, you can loosen the compression screw in the upper right corner and turn the bezel to align the hardness tester pointer to the zero position.
  2. Press the hardness tester on the flat plate, and the end surface of the pressing pin is in close contact with the bottom surface of the presser foot. At this time, the pointer should be in the range of 100 ± 1 degrees. If the pointer is not at 100 ± 1 degrees, the hardness tester cannot be used.
  3. When checking the zero position of the D-type hardness tester, a special hard gauge block must be used for testing. If the glass plate is used for inspection directly, the hardness tester pressure pin will damage the surface of the glass plate, making the inspection value inaccurate. For the specific operation method, please refer to the instruction manual of the special gauge block.
  4. Rubber samples should be prepared according to the requirements of GB / T631-99, plastic samples should be prepared according to the requirements of GB2411-80, and samples of rubber microporous materials should be prepared according to the requirements of GB2489-93.
  5. If conditions permit, rubber samples should be adjusted at the laboratory standard temperature in accordance with the provisions of GB / T2941 and GB / T2918 before testing. When the sample is tested with the A-type hardness tester, if the measured value exceeds 90 degrees, it is recommended to use the D-type hardness tester; when the sample is tested with the D-type hardness tester, if the measured value is less than 20 degrees, it is recommended to use A type hardness tester is used for testing; when the A type hardness tester is used to test the sample, if the final measurement is less than 10 degrees, the measurement result is not accurate.
  6. After the hardness tester is used, it should be wiped clean and placed in the instrument case, placed in a dry place to prevent moisture. The test bracket should be wiped frequently, and a small amount of anti-rust oil should be applied to prevent rust. In addition, No. 20 motor oil should be added to the active part. The hardness tester shall be submitted to the inspection regularly according to the provisions of JJG304-89.