Reviewed in the United States on August 29, 2024
Who has a product marketed in the US that uses METRIC pipe thread? And doesn't CLEARLY note it as a HIGH priority item in the 'feature' list?i.e. they should say in clear print the item uses "Metric BSPP" input/output fittings and will require adapters to work with ANY US standard fitting.I can't even begin to evaluate the item as I had to order $50 worth of adapters to get it to work with my STANDARD US-style water hoses....and NO, the local big box stores don't even know what you're talking about when you say "Metric pipe thread"..ONCE I get all the adapters, and test it out, I MAY add a star, maybe 2...
Manuel Espina
Reviewed in the United States on August 21, 2024
Compre este presostato para instalarlo en una red de acueducto que hice en la finca para llevarle agua a unos bebederos y funciona muy bien, fácil de instalar y programar. Me estaba presentando una falla de F--, pensaba que era la bomba o la succión de la bomba, y después de revisar varias veces la tubería de entrada me di cuenta que internamente el presostato estaba sucio, el lagua que bombeo proviene de una laguna de almacenamiento de agua lluvia y tiene material vegetal en el fondo. El manual que trae es muy básico, falta mas información
Barry H
Reviewed in the United States on August 13, 2024
Does not use US stardard pipe size. BEWARE
Kindle Customer
Reviewed in the United States on June 13, 2024
Revised my review and updated to a 4. Reason it ran and stopped was not this controller but a faulty thermal switch within the motor itself. Changed out the pump and it now works as expected. Installed it and set the starting pressure to start the pump if the pressure in the line dropped to 3 bar and had expected it to then stay on until I turned the hose off ie at the pump head max pressure. Does not appear to be the case. Just runs ok for 1-2 minutes and then switches pump off. No alarms nothing and hose is still open so why should it go off. The pressure can drop to 1.5 bar and still pump has not come back on. Thought in Mode 1 there was NO off and it would run to max head of pump. Big problem is it does not tell you why it stopped the pump, was it over pressure, was it lack of flow, you just don't know what it is doing or why. Revision:-Was too quick to blame the controller which was indicating the pump was on albeit the pump had stopped. Checked the outlet from the controller and there was power, then realized it had to be in the motor and checked to find it had thermal cut off protection which clearly was faulty.
R. Kangal
Reviewed in the United States on January 1, 2024
No wiring instructions or diagram provided for 220V supply. Seller not helpful.
CW
Reviewed in the United States on December 31, 2023
Will not run on 120volts trips the breaker and will not work. Converted my pump circuit to 240 volts (was planning on doing at a later date) and now is working as it should. Only time will tell if it is going to last !?
STEIN
Reviewed in the United States on November 10, 2023
I recently installed a submersible pump and wanted to upgrade the control system. We saw this and read about decided to try it. It's working good so far. Our pressure stays accurate according to what we set it to. Not had any issues so far seems to be a well made product. Great value for the price.